Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN Review

Let’s Dive into Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN represent a cornerstone in electrochemical analysis. They allow researchers and technicians to precisely quantify silver and sulfide ion concentrations in a variety of solutions. These electrodes are a crucial tool in environmental monitoring, industrial quality control, and scientific research. The Thermo Fisher Scientific name carries a reputation for quality and reliability, and this electrode aims to uphold that standard.

My work in environmental remediation often requires precise sulfide measurements in complex soil samples. Existing methods were cumbersome and lacked the necessary sensitivity for trace sulfide detection. I needed an instrument that could provide rapid, accurate, and reliable measurements of silver and sulfide ions in diverse sample matrices.

My initial impression upon unboxing the Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN was one of professional-grade quality. The electrode felt substantial and well-constructed, suggesting durability. The BNC connector looked robust, promising a secure connection to my meter.

I considered cheaper ion-selective electrodes from other manufacturers, as well as alternative analytical techniques such as spectrophotometry. Ultimately, I chose the Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN due to its reputation for accuracy and the established support network of Thermo Fisher Scientific. Spectrophotometry lacked the direct ion measurement I needed.

My first impression was optimistic; the sleek epoxy body and solid-state sensor instilled confidence. However, at a price of nearly $2000, it had to deliver. The proof would be in its performance.


Real-World Testing: Putting Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN to the Test

First Use Experience

I initially tested the Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN in my lab, using a series of certified silver and sulfide standard solutions. These standards ranged from 1 ppm to 100 ppm. The electrode was paired with the recommended Thermo Fisher Scientific reference electrode (34107-956).

The performance was excellent across all concentrations, with a stable reading achieved within seconds. I needed to calibrate the electrode carefully using multiple standards to generate an accurate calibration curve, as is typical with ion-selective electrodes. I encountered no major issues, although I did find that thorough rinsing between samples was crucial to prevent cross-contamination.

Extended Use & Reliability

After several months of consistent use, the Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN has proven to be a reliable workhorse in my lab. The electrode shows no signs of degradation, and the readings remain consistent with regular calibration. The electrode is stored in a recommended storage solution when not in use.

The epoxy body is durable and resistant to chemical attack from the various solutions I test. Cleaning is simple; rinsing with deionized water and gently wiping the sensor surface is usually sufficient. It has outperformed my previous ion-selective electrodes in terms of both accuracy and longevity.

Breaking Down the Features of Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN

Specifications

  • Ion Concentration Range: 107,900 to 0.01 as Ag+, 1.0 to 10-7 M; 32,100 to 0.003 as S-2, 1.0 to 10-7 M. This broad range allows for measurement of both high and low concentrations of silver and sulfide.
  • Temperature Range: 0 to 80°C. The wide temperature range makes it suitable for various lab and field applications.
  • Body Material: Epoxy. Epoxy provides chemical resistance and physical durability.
  • Type: Solid State. Solid-state sensors offer stability and long lifespans.
  • Connector: BNC. A standard BNC connector ensures compatibility with a wide range of pH/ion meters.
  • Thermo Fisher Scientific Scientific No.: 9416BN. This is the specific model number for easy identification and ordering.
  • Unit: Each. Each purchase includes one electrode.

These specifications are critical because they define the operational limits and capabilities of the electrode. The wide concentration range is particularly important for my work, where I often encounter samples with varying levels of contamination. The epoxy body ensures that the electrode can withstand harsh chemicals, and the solid-state sensor contributes to the stability and reproducibility of the measurements.

Performance & Functionality

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN excels in its ability to provide accurate and reliable measurements of silver and sulfide ions. Calibration is straightforward, and the response time is generally fast, leading to efficient analyses. The readings are stable and reproducible, provided that proper technique and calibration procedures are followed.

The main strength lies in its sensitivity and selectivity for silver and sulfide ions, which minimizes interference from other ions in the sample. A minor weakness is that the electrode requires careful handling and storage to maintain optimal performance. Overall, it exceeds my expectations in terms of accuracy, reliability, and ease of use.

Design & Ergonomics

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN features a robust epoxy body that provides a comfortable and secure grip. The electrode is lightweight, which makes it easy to handle and maneuver. The BNC connector fits snugly and securely onto my meter.

The design is functional and practical, with no unnecessary frills. There is a slight learning curve associated with calibrating and using ion-selective electrodes in general, but the Thermo Fisher Scientific documentation is clear and helpful. Overall, the design is well-suited for laboratory use.

Durability & Maintenance

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN is built to last. The epoxy body is resistant to physical damage and chemical attack, and the solid-state sensor is designed for long-term stability. Proper maintenance, including regular cleaning and storage in the recommended solution, is essential to prolong its lifespan.

The electrode is relatively easy to maintain. Regular rinsing with deionized water is usually sufficient to remove contaminants. Thermo Fisher Scientific also provides guidelines on how to regenerate the sensor if its performance degrades over time. With proper care, the electrode should provide years of reliable service.

Accessories and Customization Options

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN comes with a protective storage cap. The most important accessory is the recommended Thermo Fisher Scientific reference electrode (34107-956), which is essential for completing the electrochemical cell. The electrode itself isn’t really customizable, as it’s a specialized sensor.

However, it is compatible with a variety of pH/ion meters from Thermo Fisher Scientific and other brands, as long as they have a BNC connector. It is crucial to use appropriate calibration standards and solutions, which can be purchased separately from Thermo Fisher Scientific or other reputable suppliers. High-quality standards are crucial for accurate measurements.

Pros and Cons of Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN

Pros

  • High Accuracy and Sensitivity: Provides precise and reliable measurements of silver and sulfide ions.
  • Wide Concentration Range: Suitable for a variety of applications, from trace analysis to high-concentration measurements.
  • Durable Construction: The epoxy body and solid-state sensor are designed for long-term use.
  • Easy to Use: Simple to calibrate and operate, with clear instructions provided by Thermo Fisher Scientific.
  • BNC Connector Compatibility: Works with a wide range of pH/ion meters.

Cons

  • High Price: The initial cost is significant.
  • Requires Careful Maintenance: Proper cleaning and storage are essential for optimal performance.


Who Should Buy Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN?

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN is perfect for environmental scientists, chemists, and laboratory technicians who need accurate and reliable measurements of silver and sulfide ions. It is especially well-suited for applications in environmental monitoring, industrial quality control, and research. It’s ideal for those who require a high level of precision and reproducibility in their analyses.

This product might not be necessary for those who only need approximate measurements or who rarely analyze silver or sulfide. Cheaper, less precise methods might suffice for basic applications. Must-have accessories include a compatible pH/ion meter with a BNC input, a Thermo Fisher Scientific reference electrode (34107-956), and a set of certified silver and sulfide standard solutions for calibration.

Conclusion on Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN

The Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN is a high-quality instrument that delivers exceptional performance in silver and sulfide ion analysis. While the price is a significant investment, the accuracy, reliability, and durability of the electrode justify the cost for professionals who require precise measurements. The Thermo Fisher Scientific name provides assurance of quality and support.

I would definitely recommend this electrode to anyone who needs to accurately quantify silver and sulfide ions in complex matrices. It has become an indispensable tool in my lab, and I am confident that it will provide years of reliable service. If you value accuracy and reliability in your analytical work, then the Thermo Fisher Scientific ORION Silver/Sulfide Ion Selective Electrodes, Thermo Fisher Scientific Scientific 9416BN is an excellent choice.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top