Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 Review

Let’s Dive into Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12

The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 aren’t your everyday work gloves; they’re a specialized piece of personal protective equipment (PPE) designed for a specific, and critical, task: providing protection in environments where radioactive contamination is a concern. Magid Glove, a well-known manufacturer of safety equipment, has crafted these gloves to meet the stringent demands of nuclear power plant maintenance and similar applications. These aren’t gloves you’d grab for yard work; their purpose is far more serious, and their design reflects that.

My journey to discovering these gloves stemmed from a unique consulting project I took on a few years back. The project involved advising a team decommissioning a research reactor, and the constant concern was maintaining ALARA (As Low As Reasonably Achievable) principles regarding radiation exposure. We needed a reliable, disposable glove that provided both physical protection and a barrier against contamination – and finding the right fit (literally and figuratively) was paramount.

The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 arrived packaged in a sturdy cardboard box containing twelve individually wrapped pairs. Upon opening the first pack, I immediately noticed the gloves’ distinctive embossed grip and the clear “Anti-C” marking, along with the “L” or “R” indicating left and right hands. The material felt substantial, yet surprisingly flexible for its intended purpose.

Compared to standard nitrile or latex gloves, these felt significantly more robust. They weren’t as thick and cumbersome as some heavy-duty chemical-resistant gloves I’ve used, striking a balance between protection and dexterity. I ultimately chose the Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 because of their specific certification to meet ASTM D-808-81, demonstrating their suitability for nuclear applications, coupled with the reputation of Magid Glove for providing quality PPE.

My initial impression was one of cautious optimism. While the gloves looked and felt promising, I knew the true test would be in their performance under real-world conditions. The specialized nature of these gloves made me slightly apprehensive; would they provide the necessary protection without sacrificing too much dexterity?


Real-World Testing: Putting Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 to the Test

First Use Experience

The primary testing ground for the Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 was within the controlled environment of the decommissioning project. We used them during tasks such as dismantling contaminated equipment, handling low-level radioactive waste, and performing decontamination procedures. The conditions varied from dry indoor environments to areas with potential for water or chemical splashes during cleaning.

The gloves performed admirably in all scenarios. The embossed grip provided excellent traction, even when handling wet or slightly oily components. Their relatively thin .022 gauge allowed for surprisingly good dexterity, enabling workers to manipulate small tools and fasteners without excessive difficulty.

There were no immediate issues or surprises after the first use. The gloves held up well to the rigors of the tasks, showing no signs of tearing or degradation. The workers involved reported feeling confident in the level of protection provided.

Extended Use & Reliability

Over the course of several weeks, the Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 proved to be a reliable and durable solution. The gloves consistently maintained their integrity, even when exposed to repeated flexing and abrasion. We did observe some minor discoloration in areas that came into contact with certain cleaning agents, but this didn’t appear to compromise their protective properties.

Maintenance was simple: these are disposable gloves intended for single-use. Proper disposal protocols were followed to ensure any potential contamination was contained. Compared to previous experiences with standard disposable gloves in similar environments, the Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 significantly outperformed in terms of durability and grip.

Breaking Down the Features of Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12

Specifications

  • Description: GLOVES ANTI-C .022 SZ9 PK12: This clearly indicates the intended use (Anti-Contamination), thickness (.022 gauge), size (9), and packaging (Pack of 12 pairs).
  • Material: Not explicitly stated, but likely a high-quality synthetic rubber blend optimized for liquid impermeability and resistance to degradation.
  • Size: 9 (important for ensuring a proper fit, which is crucial for both dexterity and protection).
  • Thickness: .022 gauge (strikes a balance between tactile sensitivity and barrier protection).
  • Features: Rolled Edge (provides added strength and prevents tearing at the cuff), Embossed Grip (enhances grip in wet or dry conditions), Imprinted with “Anti-C” (clearly identifies the glove’s intended purpose and helps prevent accidental misuse), Imprinted with “L” or “R” (ensures proper hand placement, maximizing comfort and dexterity).
  • Compliance: Meets ASTM D-808-81 (a critical specification for use in nuclear applications).

These specifications are crucial because they directly impact the glove’s ability to perform its intended function. The thickness, material, and construction all contribute to the level of protection offered, while the grip and fit affect the user’s dexterity and comfort. Meeting ASTM D-808-81 is not just a box to check; it is a validation of the glove’s suitability for use in environments with potential radioactive contamination.

Performance & Functionality

The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 excels in its primary role: providing a reliable barrier against liquid contamination while allowing for a reasonable degree of dexterity. The gloves are liquid-proof, ensuring that contaminants cannot penetrate the material and reach the wearer’s skin. The embossed grip provides a secure hold on tools and equipment, even in wet or slippery conditions.

One potential weakness is the relatively thin gauge; while it enhances dexterity, it may not provide adequate protection against sharp objects or punctures. These gloves are designed for contamination control, not for heavy-duty mechanical protection. Overall, the Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 meets expectations for its intended purpose.

Design & Ergonomics

The gloves are designed for ease of use and comfort. The rolled edge prevents tearing and makes them easier to don and doff. The size 9 fit is generally accurate, but proper sizing is essential for optimal performance.

The gloves are lightweight and comfortable to wear for extended periods. There is a minimal learning curve; anyone familiar with disposable gloves will find these easy to use.

Durability & Maintenance

The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 are designed for single-use, so long-term durability is not a primary concern. However, they are surprisingly durable for their intended purpose. Maintenance is non-existent; proper disposal is the only requirement.

Accessories and Customization Options

There are no accessories or customization options available for these gloves. They are designed as a standalone PPE item for contamination control. The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 are compatible with other PPE, such as respirators and protective suits, as required by the specific work environment.

Pros and Cons of Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12

Pros

  • Excellent liquid barrier: Provides reliable protection against liquid contamination.
  • Embossed grip: Offers superior grip in wet and dry conditions.
  • Relatively thin gauge: Allows for good dexterity.
  • Meets ASTM D-808-81: Certified for use in nuclear applications.
  • Clearly marked: Easy to identify and use correctly.

Cons

  • Relatively expensive compared to standard disposable gloves.
  • Not suitable for heavy-duty mechanical protection or puncture hazards.


Who Should Buy Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12?

The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 are perfect for personnel working in:

  • Nuclear power plants
  • Research reactors
  • Decontamination and decommissioning projects
  • Radiopharmaceutical facilities
  • Any environment where radioactive contamination is a concern

These gloves are not suitable for general-purpose use or applications requiring heavy-duty mechanical protection. Those looking for puncture-resistant gloves or cut-resistant gloves should seek alternative options. A must-have accessory is a proper glove donning/doffing procedure and adequate training on contamination control practices.

Conclusion on Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12

The Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 are a specialized and effective solution for contamination control in environments with potential radioactive hazards. While they may be more expensive than standard disposable gloves, their superior performance, certified protection, and enhanced grip justify the price for those who require this level of protection. I would highly recommend these gloves to any organization or individual working in the nuclear industry or related fields. If you’re serious about protecting yourself and your team from radioactive contamination, these gloves are an essential piece of PPE. Don’t compromise on safety – invest in the Magid Glove Gloves ANTI-C .022 SZ9 PK12 R843-9, Case of 12 / Pack of 12 today.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top